4-68 centrifugal fan
Source: Release time: 2017-07-07 Click: 634 times


  • I. Overview of the fan
    The 4-68 centrifugal fan can be used as general ventilation, and its use conditions are as follows:
    1. Application place: As the indoor ventilation of general factories and large buildings, it can be used as input gas and output gas.
    2. Gas types: air and other non-combustible gases that are harmless to the human body and non-corrosive to steel materials.
    3. Impurities in the gas: No viscous substances are allowed in the gas, and the dust and hard particles are not more than 150mg / m 3 .
    4. Gas temperature: should not exceed 80 o C.
    Performance parameter table of 4-68 type centrifugal fan
    The parameters provided in the performance table are calculated according to the standard inlet state of the fan unless otherwise specified, that is, the medium is air, the pressure is 101325Pa, the temperature is 20 ℃, the density is 1.2kg / m 3 , and the relative humidity is 50% status.

    Product number Speed r / min Serial number Full pressure Pa Flow m 3 / h Electric motor
    Type Power kW
    4-68 № 2.8 A 2900 1 971 ~ 657 1131 ~ 2262 Y802-2 1.1
    1450 1 245 ~ 167 565 ~ 1131 Y801-4 0.55
    4-68 № 3.15 A 2900 1 1246 ~ 853 1825 ~ 3435 Y90S-2 1.5
    1450 1 314 ~ 216 912 ~ 1718 Y801-4 0.55
    4-68 № 3.55 A 2900 1 1608 ~ 1108 2708 ~ 5013 Y100L-2 3
    1450 1 402 ~ 275 1354 ~ 2507 Y801-4 0.55
    4-68 № 4 A 2900 1 2069 ~ 1432 3984 ~ 7281 Y112M-2 4
    1450 1 520 ~ 353 1992 ~ 3641 Y802-4 0.75
    4-68 № 4.5 A 2900 1 2658 ~ 1834 5790 ~ 10485 Y132S 2 -2 7.5
    1450 1 667 ~ 461 2895 ~ 5242 Y90S-4 1.1
    4-68 № 5 A 2900 1 3315 ~ 2305 8050 ~ 14490 Y160M 2 -2 15
    1450 1 824 ~ 579 4025 ~ 7245 Y100L 1-4 2.2
    4-68 № 6.3 D 1450 1 1324 ~ 922 8320 ~ 14761 Y132S-4 5.5
    960 1 579 ~ 402 5508 ~ 9773 Y112M-6 2.2
    4-68 № 8 D 1450 1 2158 ~ 1501 17585 ~ 30774 Y180M-4 18.5
    960 1 942 ~ 657 11643 ~ 20375 Y132M 2 -6 5.5
    730 1 549 ~ 383 8853 ~ 15403 Y132M-8 3
    4-68 № 10 D 1450 1 3442 ~ 2422 35420 ~ 61179 Y250M-4 55
    960 1 1510 ~ 1059 23450 ~ 40505 Y200L 1 -6 18.5
    730 1 873 ~ 618 17832 ~ 30801 Y160L-8 7.5
    4-68 № 12.5 D 960 1 2354 ~ 1657 45800 ~ 79111 Y280M-6 55
    730 1 1363 ~ 961 34828 ~ 60157 Y225M-8 twenty two
    4-68 № 6.3 C 2240 1 3159 ~ 2197 12852 ~ 22803 Y180M-2 twenty two
    2000 1 2511 ~ 1756 11476 ~ 20359 Y160M 2 -2 15
    1800 1 2040 ~ 1422 10328 ~ 18324 Y160M 1-2 11
    1600 1 1608 ~ 1118 9180 ~ 16287 Y132S 2 -2 7.5
    1400 1 1236 ~ 863 8032 ~ 14251 Y132S-4 5.5
    1250 1 981 ~ 687 7172 ~ 12724 Y112M-4 4
    1120 1 785 ~ 549 6426 ~ 11401 Y100L 2-4 3
    1000 1 628 ~ 441 5737 ~ 10179 Y100L 1-4 2.2
    900 1 510 ~ 353 5164 ~ 9162 Y90L-4 1.5
    800 1 402 ~ 284 4590 ~ 8144 Y90S-4 1.1
    4-68 № 8 C 1800 1 3315 ~ 2315 21830 ~ 38202 Y225S-4 37
    1600 1 2619 ~ 1834 19404 ~ 33958 Y200L-4 30
    1400 1 2010 ~ 1402 16979 ~ 29713 Y180M-4 18.5
    1250 1 1599 ~ 1118 15159 ~ 26528 Y160L-4 15
    1120 1 1285 ~ 892 13583 ~ 23770 Y160M-4 11
    1000 1 1020 ~ 716 12128 ~ 21224 Y132M-4 7.5
    900 1 834 ~ 579 10915 ~ 19101 Y132S-4 5.5
    800 1 657 ~ 461 9702 ~ 16979 Y112M-4 4
    710 1 520 ~ 363 8611 ~ 15069 Y100L 2-4 3
    630 1 402 ~ 284 7641 ~ 13371 Y100L 1-4 2.2
    4-68 № 10 C 1250 1 2560 ~ 1795 30534 ~ 52740 Y225S-4 37
    1120 1 2050 ~ 1442 27358 ~ 47256 Y200L-4 30
    1000 1 1638 ~ 1147 24427 ~ 42192 Y180L-4 twenty two
    900 1 1324 ~ 932 21984 ~ 37974 Y160L-4 15
    800 1 1049 ~ 736 19541 ~ 33754 Y160M-4 11
    710 1 824 ~ 579 17343 ~ 29956 Y132M-4 7.5
    630 1 647 ~ 461 15389 ~ 26581 Y132S-4 5.5
    560 1 510 ~ 363 13679 ~ 23627 Y112M-4 4
    500 1 412 ~ 284 12214 ~ 21096 Y100L 2-4 3
    4-68 № 12.5 C 1120 1 3207 ~ 3040 53434 ~ 66388 Y280S-4 75
    2 2903 ~ 2256 72865 ~ 92296 Y280M-4 90
    1000 1 2560 ~ 2422 47710 ~ 59276 Y250M-4 55
    2 2315 ~ 1795 65058 ~ 82407 Y280S-4 75
    900 1 2069 ~ 1451 42938 ~ 74166 Y280S-6 45
    800 1 1638 ~ 1147 38168 ~ 65926 Y225M-6 30
    710 1 1285 ~ 902 33874 ~ 58509 Y200L 2 -6 twenty two
    630 1 1010 ~ 706 30057 ~ 51917 Y180L-6 15
    560 1 804 ~ 559 26717 ~ 46148 Y160L-6 11
    500 1 638 ~ 451 23855 ~ 41204 Y160M-6 7.5
    450 1 520 ~ 363 21469 ~ 37083 Y132M 2 -6 5.5
    400 1 412 ~ 284 19084 ~ 32963 Y132M 1 -6 4
    4-68 № 16 B 960 1 3864 ~ 2717 96052 ~ 165908 Y355M 3 -6 200
    800 1 2687 ~ 2628 80043 ~ 89745 Y315M-6 90
    2 2540 ~ 1883 99448 ~ 138257 Y315L 1 -6 110
    710 1 2118 ~ 1481 71038 ~ 122703 Y315S-6 75
    630 1 1667 ~ 1167 63034 ~ 108877 Y280M-6 55
    560 1 1314 ~ 922 56030 ~ 96780 Y250M-6 37
    500 1 1049 ~ 736 50027 ~ 86410 Y225M-6 30
    450 1 853 ~ 598 45024 ~ 77769 Y200L 1 -6 18.5
    400 1 667 ~ 471 40022 ~ 69128 Y180L-6 15
    355 1 530 ~ 373 35519 ~ 61351 Y160L-6 11
    315 1 412 ~ 294 31517 ~ 54439 Y160M-6 7.5
    4-68 № 20 B 710 1 3305 ~ 2795 138747 ~ 206018 JS137-8 210
    2 2569 ~ 2324 222836 ~ 239654 JS138-8 245
    630 1 2599 ~ 1824 123113 ~ 212650 Y355M 3 -8 160
    560 1 2060 ~ 1442 109434 ~ 189023 Y315L 2 -8 110
    500 1 1638 ~ 1147 97709 ~ 168770 Y315L 1 -8 90
    450 1 1324 ~ 932 87938 ~ 151893 Y315S-8 55
    400 1 1049 ~ 736 78167 ~ 135016 Y280M-8 45
    355 1 824 ~ 579 69373 ~ 119827 Y250M-8 30
    315 1 647 ~ 461 61557 ~ 106325 Y225M-8 twenty two
    280 1 510 ~ 363 54717 ~ 94511 Y200L-8 15
    250 1 412 ~ 284 48855 ~ 84385 Y180L-8 11

    Third, the type and structure of the fan 制成 The fan is made of single suction, and the fan has two types of clockwise and counterclockwise rotation. When viewed from one end of the motor, the impeller rotating in a clockwise direction is called a clockwise rotation fan, which is expressed in clockwise, and the impeller rotating in a counterclockwise direction is called a counterclockwise rotating fan, which is expressed in a counterclockwise direction.
    位置 The outlet position of the fan is expressed by the angle of the air outlet of the casing. It can be made into six angles: 0 °, 45 °, 90 °, 135 °, 180 °, and 225 °.
    ⒊ Fan transmission mode: There are four types of A, B, C, and D. 2.8 ~ 5 adopts A type, which is directly driven by the motor. The impeller and casing of the fan are directly fixed on the motor shaft and flange; ~ 12.5 adopts cantilever support device, which is divided into two types: C type (belt drive) and D type (coupling drive); №16 and 20 are belt drive of B type cantilever support device, and the pulley is installed in the middle of the bearing.
    №2.8 ~ 5 of the fan are mainly composed of direct-connected motors distributed by impellers, casings, air inlets, etc. №6.3 ~ 20 have transmission parts in addition to the above.
    4. Installation, adjustment and trial operation of the fan⒈ Before installation: A comprehensive inspection should be carried out on each part of the fan to see if the parts are complete, whether the direction of rotation of the impeller and the casing is consistent, whether the parts are tightly connected, and the impeller, main shaft, and bearings Whether the main parts are damaged, whether the transmission group is flexible and so on. If problems are found, they should be fixed and adjusted immediately.
    ⒉ During installation: Pay attention to check the case. There should be no tools and sundries falling into the case. On some joint surfaces, in order to prevent rust and reduce disassembly difficulties, some grease and mechanical oil should be applied. . The connection surface between the fan and the foundation, the inlet and outlet ducts should be adjusted so that they fit naturally. It must not be forcibly connected, and the pipe weight must not be added to each part of the fan. Pay attention to ensure the horizontal position of the fan.
    ⒊ Installation requirements ① Install according to the position and dimensions shown in the drawing. In order to ensure high efficiency, the axial and radial clearance dimensions of the air inlet and the impeller must be especially ensured.
    ② When installing №6.3 ~ 12.5D type fan, it is necessary to ensure the horizontal position of the fan main shaft and the coaxiality of the motor shaft. The installation of the coupling must meet the technical requirements for the installation of flexible couplings.
    For C-type transmission fans, the grooves of the main shaft V-belt and the motor V-belt must not be misaligned.
    ③ After installation: try to pull out the transmission unit to check if it is too tight or collided. If it is found to be wrong, it must be adjusted.
    的 The trial operation of the fan is completely installed, and the trial operation can be performed only after the general inspection is passed.
    In order to prevent the motor from being burned due to overload, the fan must be started and commissioned without load (close the gate in the pipeline). If the condition is good, then the continuous operation test of normal conditions (specified full pressure and flow rate) of the sluice is then opened at full load. The trial run time of the new installation is not less than 2 hours, and the trial run time of the repair and installation is not less than half an hour. If there is no abnormal phenomenon, it can be officially used.
    The power used by the fan refers to the power consumption and the safety factor due to mechanical loss under specific working conditions. During the operation, the current should be strictly controlled, and the rated value of the motor must not be exceeded, otherwise the motor will be burned.
    V. Operation of the fan⒈ Before starting the fan, the following preparations should be performed:
    ① Close the gate.
    ② Check the clearance size of each part of the fan, and check whether there is collision or friction between the rotating part and the fixed part.
    ③ In the radial direction of the impeller, no one should stand near the coupling or the pulley. To avoid danger. Couplings or pulleys should be equipped with safety covers.
    ④ Check whether the bearing lubricant is sufficient.
    ⒉ When the fan reaches normal speed after starting, gradually open the large gate until the specified load. During the running process, the temperature rise of the bearing should not be higher than 40 ℃, and the temperature of the table should not be higher than 70 ℃.
    ⒊ If abnormal phenomena such as severe vibration, impact and rapid temperature rise of the fan are found, the machine must be stopped immediately to find out the cause.
    6. Fan maintenance <br /> In order to avoid human failures and accidents caused by improper maintenance, prevent natural failures in various aspects of fans and motors, so as to give full play to the effectiveness of the equipment and extend the service life of the equipment. Therefore, the maintenance of fans must be strengthened.
    1. Precautions for fan maintenance work:
    (1) Operate only when the fan equipment is completely normal.
    (2) If the fan equipment is started after maintenance, pay attention to whether the parts of the fan are normal.
    (3) Regularly check the dust, dirt and other impurities inside the fan and gas transmission pipeline, and prevent rust.
    (4) In order to ensure personal safety, the maintenance work of the fan must be carried out while stopping.
    2. Precautions during normal fan operation:
    (1) If it is found that the flow is too large, does not meet the requirements for use, or requires less flow for a short period of time, the gate can be adjusted to meet the requirements for use.
    (2) The sensitivity of the thermometer and oil gauge of the bearing box should be checked regularly.
    (3) In the process of driving, stopping or running the fan, if any abnormality is found, it should be checked immediately.
    (4) For minor faults found during inspection, the cause should be found in time to eliminate them. If major faults are found, they should be stopped immediately for maintenance.
    (5) In addition to changing the lubricant after each disassembly, the lubricant should also be changed regularly under normal circumstances.
    (6) It is necessary to correct the slippage when the belt is elongated.
    7. Causes of failures during fan operation剧烈 Vibration of the bearing box is severe:
    (1) Friction between the casing or the air inlet and the impeller;
    (2) the stiffness of the foundation is insufficient or not strong;
    (3) The impeller rivet is loose or the impeller is deformed;
    (4) The hole of the impeller shaft disc is loosely matched with the shaft, and the coupling bolt is loose;
    (5) Loose bolts such as casing and bracket, bearing box and bracket, bearing box cover and bearing seat are loose;
    (6) Poor installation of air inlet and outlet pipes of fans;
    (7) The impeller is deformed, the blades are worn, the blades have ash, dirt and shaft bending, which makes the rotor unbalanced;
    (8) The fan shaft is not concentric with the motor shaft, and the coupling is misaligned.
    轴承 Bearing temperature rise is too high:
    (1) The bearing box vibrates violently;
    (2) The grease is of poor quality, deteriorates, and contains impurities, such as dust, sand, dirt, etc., or the filling amount is improper;
    (3) The tightening force of the bearing box cover and the seat bolt is too large or too small;
    (4) The shaft and rolling bearing are installed at an angle, and the front and rear bearings are not concentric;
    (5) The rolling bearing is damaged or the shaft is bent.
    电动机 Excessive motor current and excessive temperature rise:
    (1) The gate or throttle in the intake duct is not closed tightly when driving;
    (2) The density of the gas delivered by the fan is too high or the temperature is too low, which makes the pressure too large;
    (3) The input voltage of the motor is too low, the single-phase power failure of the power supply or the speed of the motor increases;
    (4) The coupling is incorrectly connected, the aprons are too tight or the gaps are uneven.
    (5) Affected by the severe vibration of the bearing box.
    VIII. Complete supply range of stand-alone products ① The transmission mode is A: One fan, one supporting motor, one set of anchor bolts (4 sets).
    ② The transmission method is C, B: one fan, one supporting motor, one pair of motor slides (two sets), one pair of anchor bolts (№6.3: 4 sets, №8 or more), one motor pulley , A pair of triangle tape.
    ③ The transmission method is D: one fan, one supporting motor, one set of anchor bolts (№6.3: 4 sets, №8 or more 8 sets), and a set of couplings.
    Nine, ordering instructions <br /> When ordering, the machine number, speed, flow rate, pressure, air outlet angle and rotation direction of the fan must be indicated, as well as the motor model, power, and number of revolutions.


  • Yunnan Jingge Ventilation Equipment Co., Ltd.
  • Dabanqiao Industrial Park, Guandu District, Kunming City, Yunnan Province
  • 714328283@qq.com
  • hotline:
  • 13759168650
  • Jing grid fan-believe in the power of the brand
Copyright © Yunnan Jingge Ventilation Equipment Co., Ltd. All Rights Reserved. Dian ICP No.16007375-1 Website Construction Technical Support: Yunnan Dinghao Information Technology Co., Ltd
七乐彩 欢乐拼三张 欢乐拼三张 天天电玩城