  • I. Use

    The 4-79 type centrifugal fan (hereinafter referred to as fan) can be used for general ventilation and ventilation .
    1. Application place: As the indoor ventilation of general factories and large buildings, it can be used as input gas and output gas.   
    2. Impurities in the gas: No viscous substances are allowed in the gas, and the dust and hard particles contained in the gas are not more than 150mg / m 3 .   
    3. Gas types: air and other gases that are not spontaneous, harmless to the human body, and non-corrosive to steel materials.
    4. Gas temperature: should not exceed 80 o C.
    III. Performance parameter table for 4-79 type double inlet centrifugal fan < br The parameters provided in the performance table are calculated according to the standard inlet state of the fan unless otherwise specified, that is, the medium is air, the pressure is 101325Pa, the temperature The standard state is 20 ° C, density is 1.2kg / m 3 , and relative humidity is 50%.
    Product number Rotating speed
    r / min
    Serial number Full pressure Pa Flow m 3 / h Electric motor
    Type Power kW
    4-79 № 2-5 E 2000 1 1607 ~ 1206 13600 ~ 18820 Y160M-4 11
    1800 1 1382 ~ 941 9850 ~ 17160 Y132M-4 7.5
    1550 1 1010 ~ 647 9620 ~ 15320 Y132S-4 5.5
    1350 1 774 ~ 480 7980 ~ 13340 Y112M-4 4
    1200 1 618 ~ 412 6380 ~ 11640 Y100L 1-4 2.2
    1050 1 471 ~ 314 5580 ~ 10180 Y90L-4 1.5
    900 1 343 ~ 235 4780 ~ 8630 Y90S-4 1.1
    4-79 № 2-6 E 1800 1 1990 ~ 1362 16760 ~ 29820 Y180M-4 18.5
    1650 1 1676 ~ 1186 15190 ~ 27000 Y160L-4 15
    1500 1 1392 ~ 990 13660 ~ 24550 Y160M-4 11
    1400 1 1215 ~ 814 12890 ~ 23490 Y132M-4 7.5
    1200 1 882 ~ 588 10990 ~ 20070 Y132S-4 5.5
    1050 1 676 ~ 461 9610 ~ 17560 Y112M-4 4
    900 1 500 ~ 333 8240 ~ 15050 Y100L 2-4 3
    800 1 392 ~ 265 7360 ~ 13380 Y100L 1-4 2.2
    4-79 № 2-7 E 1600 1 1970 ~ 1166 24930 ~ 48330 Y200L-4 30
    1250 1 1206 ~ 716 19470 ~ 37710 Y160L-4 15
    1120 1 970 ~ 549 17370 ~ 33840 Y160M-4 11
    1000 1 774 ~ 461 15570 ~ 30240 Y132M-4 7.5
    900 1 627 ~ 473 14000 ~ 27180 Y132S-4 5.5
    800 1 500 ~ 294 12450 ~ 24190 Y112M-4 4
    710 1 392 ~ 235 10990 ~ 21420 Y100L 2-4 3
    4-79 № 2-8 E 1270 1 1570 ~ 932 23760 ~ 52960 Y200L-4 30
    1120 1 1226 ~ 726 24080 ~ 46720 Y180L-4 twenty two
    1000 1 971 ~ 579 21520 ~ 41680 Y160L-4 15
    900 1 785 ~ 471 19360 ~ 37600 Y160M-4 11
    800 1 618 ~ 373 17210 ~ 33360 Y160M-4 11
    710 1 491 ~ 294 15230 ~ 30080 Y160M-6 7.5
    650 1 387 ~ 226 13520 ~ 26320 Y132M 2 -6 5.5
    4-79 № 2-10 E 1300 1 2607 ~ 1774 77000 ~ 127000 Y315S-4 110
    1170 1 2117 ~ 1441 69200 ~ 114200 Y280S-4 75
    1040 1 1666 ~ 1147 61500 ~ 102600 Y250M-4 55
    940 1 1362 ~ 931 55700 ~ 91800 Y225M-4 45
    830 1 1058 ~ 725 49100 ~ 81000 Y200L-4 30
    740 1 843 ~ 578 43800 ~ 72200 Y180M-4 18.5
    660 1 666 ~ 461 39000 ~ 64400 Y180L-6 15
    580 1 519 ~ 353 34320 ~ 56600 Y160L-6 11
    520 1 412 ~ 284 30800 ~ 50800 Y160M-6 7.5
    4-79 № 2-12 E 1040 1 2391 ~ 1637 106600 ~ 175600 Y315M 1-4 132
    940 1 1950 ~ 1333 96400 ~ 158600 Y315S-4 110
    830 1 1529 ~ 1039 85000 ~ 140200 Y315S-6 75
    740 1 1215 ~ 823 75800 ~ 124800 Y280M-6 55
    680 1 1039 ~ 696 99700 ~ 114800 Y280S-6 45
    580 1 755 ~ 510 59400 ~ 97800 Y200L 2 -6 twenty two
    520 1 603 ~ 402 53300 ~ 87800 Y180L-6 15
    470 1 490 ~ 333 48200 ~ 79400 Y160L-6 11
    420 1 387 ~ 265 43000 ~ 70900 Y160M-6 7.5
    4-79 № 2-14 E 850 1 2185 ~ 1490 138300 ~ 227000 JS-126-6 155
    740 1 1656 ~ 1127 120200 ~ 197800 Y315M 1 -6 90
    660 1 1401 ~ 951 110600 ~ 181800 Y315S-6 75
    580 1 1019 ~ 686 94200 ~ 155000 Y280M-6 55
    520 1 813 ~ 549 84400 ~ 139000 Y225M-6 30
    460 1 637 ~ 431 74600 ~ 123000 Y200L 2 -6 twenty two
    420 1 529 ~ 363 68100 ~ 112400 Y200L 1 -6 18.5
    370 1 412 ~ 274 60000 ~ 98800 Y180L-6 15
    330 1 323 ~ 225 53600 ~ 88200 Y160L-6 11
    4-79 № 2-16 E 740 1 2176 ~ 1480 171400 ~ 295600 JS-127-6 185
    660 1 1725 ~ 1176 160200 ~ 263800 Y315M 3 -6 132
    580 1 1333 ~ 902 140600 ~ 231800 Y315M 1 -6 90
    510 1 1029 ~ 696 123400 ~ 203800 Y315S-6 75
    470 1 872 ~ 598 113800 ~ 188000 Y280M-6 55
    420 1 696 ~ 480 101600 ~ 168000 Y280S-6 45
    370 1 539 ~ 372 89600 ~ 148400 Y225M-6 30
    330 1 431 ~ 294 80000 ~ 132200 Y200L 1 -6 18.5
    290 1 333 ~ 225 70200 ~ 116000 Y200L-8 15
    4-79 № 2-18 E 660 1 2185 ~ 1490 228000 ~ 375800 JS-136-6 240
    580 1 1686 ~ 1147 200400 ~ 330200 JS-128-8 155
    520 1 1362 ~ 931 179800 ~ 296200 JS-127-8 130
    470 1 1107 ~ 755 162400 ~ 267600 Y315M 2 -8 90
    420 1 882 ~ 598 145000 ~ 239000 Y315M 1 -8 75
    360 1 647 ~ 431 124200 ~ 205000 Y280M-8 45
    330 1 549 ~ 363 113800 ~ 188000 Y250M-8 30
    290 1 421 ~ 284 100800 ~ 165200 Y225M-8 twenty two
    260 1 343 ~ 225 89600 ~ 148200 Y200L-8 15
    4-79 № 2-20 E 560 1 1940 ~ 1313 625600 ~ 438000 JS-138-8 245
    520 1 1676 ~ 1137 246800 ~ 406000 JS-137-8 210
    470 1 1372 ~ 931 222000 ~ 367000 JS-127-8 130
    420 1 1088 ~ 745 199200 ~ 327400 Y315M 2 -8 90
    370 1 843 ~ 578 175600 ~ 288200 Y315M 1 -8 75
    330 1 676 ~ 461 156600 ~ 257200 Y315S-8 55
    290 1 519 ~ 353 137600 ~ 226000 Y280M-8 45
    260 1 421 ~ 284 123400 ~ 202800 Y250M-8 30

    Fourth, the type and structure of the fan <br /> Fan can be made into two types of clockwise rotation and counterclockwise rotation. When viewed from one end of the motor, the impeller rotating in a clockwise direction is called a clockwise rotation fan, which is expressed in clockwise; the impeller rotating in a counterclockwise direction is called a counterclockwise rotating fan, which is expressed in a counterclockwise direction.
    The outlet position of the fan is indicated by the outlet angle of the casing. The 4 ~ 79 type fans №3 ~ №12 are made into a type before leaving the factory, and the user unit is reinstalled to the required position according to requirements. Do not specify when ordering. №3 outlet position adjustment range is 0 ° ~ 225 °, the interval is 45 °. №3.5 ~ 6 The position of the air outlet can be adjusted from 0 ° to 225 °, and the interval is 22.5 °. №3 ~ 6's transmission method is A-type transmission. The position adjustment range of №7 ~ 8 air outlet is 0 ° ~ 180 °, the interval is 22.5 °, the transmission method of №7 ~ 8 is C type transmission, and the transmission method of №10 ~ 20 is E type transmission. №10 ~ 20 air outlet positions are made of three fixed types: 0 °, 90 °, and 180 °, which cannot be adjusted. Please specify when ordering. №5 ~ 20 double air inlet types are all made of three fixed air outlet positions: 0 °, 90 °, 180 °. The transmission mode is E-type transmission, which must be specified when ordering.
    №3 ~ 6 of 4-79 type fan are mainly composed of direct-connected motors distributed by impeller, casing, air inlet, etc. №7 ~ 20 have transmission parts in addition to the above parts.
    Fifth, the installation and use of the fan < br 安装 Before installation, first prepare the installation materials and tools, and check the parts of the fan. The impeller, the main shaft, and the bearings should be inspected particularly carefully. If damage is found, it should be repaired, and then the inside of the bearing box should be cleaned with kerosene.
    The following points must be noted during the installation process:
    1. On some joints, in order to prevent rust and reduce disassembly difficulties, some grease or mechanical oil should be applied.
    2. When fixing the bolts on the joint surface, if there are positioning pins, the pins should be tightened before tightening the bolts.
    3. Check the inside of the cabinet and other casings, and there should be no falling tools or debris.
    Installation requirements:
    ⒈ When installing the fan, the weight of the gas pipeline should not be added to the casing. Pay attention to the size of the gap between the air inlet and the impeller, and maintain the axial horizontal position.
    ⒉ When installing the air inlet pipe, you can directly use the bolt of the air inlet itself to connect. At this time, the air inlet is fixed by three countersunk screws.
    时 When the air outlet is installed at an angle, the rear disc is properly rotated to keep the label in a horizontal position. Among them, №7 ~ 12 angle steel flange surface should be kept horizontal.
    后 After the fan is installed, move the rotor by hand or lever to check whether there is excessive tightening or collision. Only test the rotation without these phenomena.
    后 After the motor is installed, install the pulley guard. If the air inlet is not connected to the air inlet duct, it is also necessary to add protective nets or other safety devices (user-supplied).
    The power of the electric motor used in the ventilator refers to the power required under the specific working conditions, plus mechanical losses and due reserves, when the air outlet is fully open. If the outlet or inlet of the fan is run dry without being connected to the pipeline or without external resistance, the motor may also be burned. For safety reasons, a valve should be added to the fan's outlet or inlet pipeline, and it should be closed when the motor is started, and the valve should be opened slowly after running until the specified operating conditions are reached, and pay attention to whether the motor current exceeds the specified value.
    6. Fan maintenance <br /> In order to avoid human failures and accidents caused by improper maintenance, prevent natural failures and accidents in all aspects of fans and motors, so as to give full play to the effectiveness of the equipment and extend the service life of the equipment, It is necessary to strengthen the maintenance of the fan.
    制度 Fan maintenance work system Fan maintenance personnel must pay attention to the following points:
    1. Operate only when the fan equipment is completely normal.
    2. If the fan equipment is started after maintenance, please pay attention to whether all parts of the fan are normal.
    3. Regularly remove dust, dirt, water and other impurities inside the fan and gas transmission pipeline, and prevent rust.
    4. Repair of fan equipment must not be performed during operation.
    注意 Precautions during normal fan operation
    1. If it is found that the flow is too large, does not meet the requirements for use, or requires less flow in a short period of time, it can be adjusted with a throttling device.
    2. The sensitivity of thermometers and oil labels should be checked regularly.
    3. During the driving, stopping or running of the fan, if any abnormality is found, it should be repaired immediately.
    ⒋ For minor faults found in the inspection, the cause should be found in time to eliminate or deal with them. If minor faults cannot be eliminated, or major faults are found, they should be repaired immediately.
    ⒌ In addition to changing the lubricant after each disassembly, the lubricant should also be changed regularly.
    主要 The main faults and causes of the fan During the operation of the fan, some faults may occur. For the faults that occur, the cause must be quickly identified and resolved in time to prevent accidents.
    The main faults of the fan are:
    1. The bearing box vibrates violently ① The casing or air inlet rubs against the impeller.
    ② The stiffness of the foundation is insufficient or not strong.
    ③ The impeller rivets are loose or the disk is deformed.
    ④ The impeller shaft disc and shaft are loose.
    ⑤ The connecting bolts such as casing and bracket, bearing box and bracket, bearing box cover and seat are loose.
    ⑥ The installation of the air inlet and outlet pipes of the fan is not good, and vibration occurs.
    不 The rotor is unbalanced.
    2. The temperature of the bearing is too high ① The bearing box vibrates violently.
    ② Poor lubricating quality, deterioration, or excessive filling with impurities such as dust, sand, dirt, etc.
    ③ The tightening force of the bearing box cover and seat connection bolt is too large or too small.
    ④ The shaft and rolling bearing are installed at an angle, and the front and rear bearings are not aligned.
    ⑤ The rolling bearing is damaged.
    3. The motor current is too high and the temperature rise is too high ① The gate or throttle in the intake duct is not closed when driving.
    ② The flow exceeds the specified value or the air pipe is leaking.
    ③ The density of the gas delivered by the fan is too large, which makes the pressure too large.
    ④ The input voltage of the motor is too low or the single-phase power supply is cut off.
    ⑤ Affected by the severe vibration of the bearing box.
    4. The belt slides off. The two pulleys are not on the center line of each other, so that the belt slides off the small pulley.
    5. The belt jumps. The two pulleys are too close or the belt is too long.

  • Yunnan Jingge Ventilation Equipment Co., Ltd.
  • Dabanqiao Industrial Park, Guandu District, Kunming City, Yunnan Province
  • 714328283@qq.com
  • hotline:
  • 13759168650
  • Jing grid fan-believe in the power of the brand
Copyright © Yunnan Jingge Ventilation Equipment Co., Ltd. All Rights Reserved. Dian ICP No.16007375-1 Website Construction Technical Support: Yunnan Dinghao Information Technology Co., Ltd
七乐彩 欢乐拼三张 欢乐拼三张 天天电玩城