9-26 high pressure centrifugal fan
Source: Release time: 2017-07-07 Click: 641 times

帕,风量3407-123090万立方/小时,风9-26离心风机本风机为单吸入式,通常有9-26 4A、4.5A、5A、5.6A、6.3A、7.1D、8D、9D、10D、11.2D、12.5D、14D、16D共13个机号。 9-26 high pressure centrifugal fan is one of the most commonly used high pressure forced air fans. It is widely used in kiln, metallurgy, building materials, chemical industry and other industries. The power is from 5.5kw to 850kw, the wind pressure is 2198-16250 Pa, and the air volume is 3407-123090. 10,000 cubic meters / hour, wind 9-26 centrifugal fan This fan is single-suction, usually 9-26 4A, 4.5A, 5A, 5.6A, 6.3A, 7.1D, 8D, 9D, 10D, 11.2D, 12.5D , 14D, 16D a total of 13 aircraft numbers.
This fan is usually made into two types of right-handed and left-handed. When viewed from one end of the motor, the clockwise rotation of the impeller is called the right-handed fan, and the clockwise rotation is called the left-handed fan, and the left-handed fan.
The exit position of the fan is indicated by the exit angle of the casing. "Left" and "right" can be made into six angles: 0 degrees, 45 degrees, 90 degrees, 135 degrees, 180 degrees, and 225 degrees.
The transmission mode of the fan is divided into three types: A type (No. 4-6.3), D type and C type (No. 7.1-16).

This fan has four types: ordinary (9-26), explosion-proof (B9-26), anti-corrosion (F9-26), and high-temperature (W9-26).
Second, 9-26 high-pressure centrifugal fan specifications and performance technical parameter table

Machine number
Rotating speed
Serial number
Full pressure
flow
Matching motor
r / min
m3 / h
pa
model
Power kw
9-26 4A
2900
1
3852
2198
Y132S1-2
5.5
2
3820
2368
3
3765
2536
4
3684
2706
5
3607
2877
6
3502
3044
7
3407
3215
9-26 4.5A
2900
1
4910
3130
Y132S2-2
7.5
2
4863
3407
3
4776
3685
4
4661
3963
Y160M1-2
11
5
4545
4237
6
4412
4515
7
4256
4792
9-26 5A
2900
1
6035
4293
Y160M2-2
15
2
5984
4706
3
5869
5114
4
5725
5527
5
5553
5941
6
5381
6349
7
5180
6762
Y160L-2
18.5
9-26 5.6A
2900
1
7610
6032
Y180M-2
twenty two
2
7546
6612
3
7400
7185
4
7218
7766
5
7000
8346
6
6781
8919
7
6527
9500
Y200L1-2
30
9-26 6.3A
2900
1
9698
8588
Y225M-2
45
2
9616
9415
3
9429
10230
4
9195
11056
Y250M-2
55
5
8915
11883
6
8636
12699
7
8310
13525
9-26 7.1D
2900
1
12427
12292
Y280S-2
75
2
12321
13475
3
12078
14643
4
11776
15826
Y315S-2
110
5
11415
17009
6
11055
18177
7
10635
19360
9-26 8D
2900
1
15955
17584
Y315M-2
132
2
15818
19277
3
15504
20947
4
15112
22640
Y315L2-2
200
5
14644
24332
6
14177
26003
7
13634
27696
9-26 8D
1450
1
3834
8792
Y180M-2
18.5
2
3802
9639
3
3729
10473
4
3638
11320
5
3529
12166
6
3421
13001
Y200L-4
30
7
3294
13848
9-26 9D
1450
1
4869
12518
Y200L-4
30
2
4828
13723
3
4736
14913
4
4620
16118
Y225M-4
45
5
4481
17322
6
4434
18512
7
4181
19717
9-26 10D
1450
1
6143
17172
Y250M-4
55
2
6056
19319
3
5920
21465
4
5761
23612
Y280S-4
75
5
5560
25758
6
5309
27905
7
5065
30052
9-26 11.2D
1450
1
7747
24126
Y315S-4
110
2
7637
27142
3
7464
30157
4
7264
33173
5
7009
36189
6
6691
39205
Y315M-4
132
7
6382
42221
9-26 11.2D
960
1
3346
15973
Y225M-6
30
2
3299
17969
3
3225
19966
4
3140
21963
5
3031
23959
Y250M-6
37
6
2895
25956
7
2763
27953
9-26 12.5D
1450
1
9713
33540
Y315L-4
160
2
9575
37732
3
9356
41925
4
9103
41117
Y355M2-4
250
5
8782
50310
6
8381
54503
7
7993
58695
9-26 12.5D
960
1
4179
22206
Y280S-6
45
2
4121
24981
3
4028
27757
4
3921
30533
Y315S-6
75
5
3785
33309
6
3615
36084
7
3450
38860
9-26 14D
1450
1
12285
47121
Y355M2-4
250
2
12109
53011
3
11830
58902
JS138-4
410
4
11508
64792
5
11099
70682
6
10589
76572
7
10095
82463
9-26 14D
960
1
5262
31197
Y315S-6
75
2
5188
35097
3
5071
38997
Y315L1-6
110
4
4936
42897
5
4764
46796
6
4549
50696
7
4341
54596
9-26 16D
1450
1
16250
70339
JSQ-147-4 (3000V)
500
2
16014
79131
3
15640
87923
JSQ-158-4 (3000V)
850
4
15210
96716
5
14663
105500
6
13983
114300
7
13324
123090
9-26 16D
960
1
6911
46569
Y355M2-6
185
2
6813
52390
3
6659
58211
4
6481
64032
5
6254
69854
6
5971
75675
Y355L1-6
220
7
5696
81496

Installation and maintenance of 9-26 high pressure centrifugal fan

Before installation: All parts of the fan should be thoroughly inspected, whether the parts are complete, whether the direction of rotation of the impeller and the casing is consistent, and whether the parts are tightly connected. Whether impeller, main shaft, bearing and other main parts are damaged, and whether the transmission group is flexible.
During installation: Pay attention to check the cabinet. There should be no tools or sundries falling or left in the cabinet. In order to prevent rust and reduce disassembly difficulties on some joint surfaces, a layer of grease or mechanical oil should be applied. The fan and the foundation are fully integrated. When the air inlet and outlet pipes are connected, adjust to make them fit naturally. Do not force the connection. Do not add the weight of the pipe to the fan components, and pay attention to ensure the horizontal position of the fan.
Installation requirements:
(1) Install according to the position and size shown in the drawing. In order to ensure high efficiency, especially the axial clearance and radial clearance dimensions of the air inlet and outlet and the impeller.
(2) Test the transmission group after installation to check whether it is too tight or colliding with the fixed part.
(3) After the installation is completed and the general inspection is qualified, the test run of the fan can be performed.
In order to prevent the motor from being overloaded and burned, when the fan is started, it must be carried out under no load (close the air inlet valve and the air outlet valve is slightly open). If the condition is good, gradually open the valve until the specified operating conditions. The current should be strictly controlled during operation and must not exceed the rated value.
Operation of the fan:
(1) Before starting the fan, perform the following preparations: a. Close the air inlet valve and open the air outlet valve slightly. b. Check the gap size of each part of the fan, and check whether there is collision and friction between the rotating part and the fixed part.
(2) When the fan reaches normal speed when starting, the bearing should be checked regularly during operation. When there is no special requirement for the shaft temperature, the temperature rise of the bearing must not exceed the ambient temperature of 40 ° C; 6.3m / s. If it is found that the fan has severe vibration, impact, and rapid rise in bearing temperature, it must be stopped immediately.

1. Precautions for maintenance of fans:
a. It can only run when the fan equipment is completely normal.
b. If the fan equipment is started after maintenance, pay attention to whether all parts of the fan are normal.
C. Regularly remove dust, dirt and other impurities inside the fan, and prevent rust.
d. In order to ensure personal safety, the maintenance of the fan must be carried out while stopping.
2. Attentions for normal fan operation:
a. In the process of fan driving, stopping or running, if abnormality is found, it should be checked immediately. If there is a small fault, the cause should be found in time to eliminate it. If a major fault is found, it should be stopped for maintenance immediately.
b. Except that the lubricant should be replaced after each inspection, the lubricant is normally changed according to the actual situation.
Performance and selection of 9-26 high pressure centrifugal fan

Dimensionless performance table and curve of №10 prototype. Calculate the dimensioned performance of fans above №10 from the dimensionless performance table or curve given.
K—The reserve factor of the motor When the use state is non-standard state, the performance of the non-standard state must be converted to the performance of the standard state, and then the fan is selected according to the conversion performance. The conversion formula is as follows:
Q0 / Q = n0 / n ?? (m3 / h)
P0 / P = (n0 / n) 2 (ρ0 / ρ) (Kp / Kp0) ?? (Pa)
Nin0 / Nin = (n0 / n) 2 (ρ0 / ρ) ??? (kw)
ηin0 = ηin
In the formula:
ηin—internal power
n—speed (r / min)

9-26 Dimensionless Performance Table of 10D Prototype Table 1

1

2

3

4

5

6

7

Φ

0.03

0.037

0.044

0.051

0.058

0.065

0.072

Ψ

0.828

0.842

0.835

0.814

0.78

0.745

0.705

Ψd

0.0478

0.0725

0.1025

0.1380

0.1793

0.2263

0.2792

lambda

0.03247

0.0389

0.0451

0.05125

0.05785

0.065

0.0725

ηmin

0.765

0.800

0.815

0.81

0.782

0.75

0.700

9-26 Dimensionless Performance Table of 10D Prototype Table 1

1

2

3

4

5

6

7

Φ

0.08

0.09

0.1

0.11

0.12

0.13

0.14

Ψ

0.87

0.858

0.839

0.817

0.789

0.754

0.72

Ψd

0.0745

0.0943

0.1167

0.1416

0.1692

0.1904

0.2323

lambda

0.0866

0.0951

0.1044

0.1143

0.1246

0.1343

0.144

ηmin

0.804

0.812

0.804

0.786

0.76

0.73

0.70

Motor reserve factor


Shaft power kw

<0.5

> 0.5 ~ 1

> 1 ~ 2

> 2 ~ 5

> 5

K

1.5

1.4

1.3

1.2

1.15

Fan performance generally refers to the performance of conveying gas under standard conditions. The standard state refers to atmospheric pressure pa = 101300pa, atmospheric temperature t = 20 ° C, relative temperature 50%, and air density ρ = 1.2kg / m3.

V. Common faults and causes of 9-26 high pressure centrifugal fans
1. The fan vibrates violently. The fan shaft and the motor shaft are not concentric, and the pulley grooves are misaligned.
Friction between the casing or the air inlet and the impeller;
The stiffness of the foundation is insufficient or weak;
Impeller rivets loose or deformed;
The impeller shaft disc hole is loose with the shaft
Loose connection bolts of housing, bearing housing and bracket, bearing housing and bearing cover
Insufficient installation of fan inlet and outlet pipelines, causing resonance
The blade has ash deposits, dirt, blade wear, impeller deformation, shaft bending and other reasons that make the rotor imbalance.
2. The bearing temperature rises too high.
Lubricant is of poor quality, deteriorates or contains impurities such as dust, sand, dirt, etc., or the filling amount is insufficient;
The tightening force of the bearing box cover and seat connecting bolt is too large or too small;
The shaft and the rolling bearing are installed at an angle, and the front and rear axes are not concentric;
Damaged rolling bearings or bent shafts.
3. When the motor current is too high or the temperature rise is too high, the gates of the inlet and outlet pipes are not closed when driving;
Low motor input voltage or single phase power failure
Affected by severe vibration of the bearing box
Spindle speed exceeded rated value.
6. Selection of 9-26 high pressure centrifugal fan You can choose from the performance parameters (note: the parameters in the parameter table are standard operating conditions, the medium temperature is 20 degrees Celsius), and we can also provide air volume, wind pressure, and medium temperature. Type, quote. When necessary, special-shaped fans can be designed and manufactured; explosion-proof, anti-corrosive, and high-temperature resistant types can also be designed and manufactured according to the operating conditions .
Seven, 9-26 high-pressure centrifugal fan dimensions and foundation drawings, please call for details.

  • Yunnan Jingge Ventilation Equipment Co., Ltd.
  • Dabanqiao Industrial Park, Guandu District, Kunming City, Yunnan Province
  • 714328283@qq.com
  • hotline:
  • 13759168650
  • Jing grid fan-believe in the power of the brand
Copyright © Yunnan Jingge Ventilation Equipment Co., Ltd. All Rights Reserved. Dian ICP No.16007375-1 Website Construction Technical Support: Yunnan Dinghao Information Technology Co., Ltd
七乐彩 欢乐拼三张 欢乐拼三张 天天电玩城