9-19 high pressure centrifugal fan
Source: Release time: 2017-07-07 Click: 645 times

Machine number
Rotating speed
r / min
Serial number
Full pressure
Pa
flow
m3 / h
Required power
KW
electric motor
model
power
KW
9-19 4A
2900
1
2
3
4
5
6
7
3584
3665
3647
3597
3507
3384
3253
824
970
1116
1264
1410
1558
1704
1.5
1.7
1.9
2.1
2.3
2.6
2.6
Y90L-2
2.2
Y100L-2
3
9-19 4.5A
2900
1
2
3
4
5
6
7
4603
4684
4672
4580
4447
4292
4112
1174
1397
1616
1839
2062
2281
2504
2.5
2.9
3.2
3.6
3.9
4.4
4.8

Y112M-2

4

Y132S1-2

5.5

9-19 5A
2900
1
2
3
4
5
6
7
5697
5768
5740
5639
5517
5323
5080
1610
1932
2254
2576
2844
3166
3488
4.1
4.8
5.4
5.8
6.4
7.1
7.9

Y132S-2

7.5

Y160M1-2

11

9-19 5.6A
2900
1
2
3
4
5
6
7
7182
7273
7236
7109
6954
6709
6400
2262
2714
3167
3619
3996
4448
4901
7.0
8.1
9.1
10.2
11.2
12.5
13.9
Y160M1-2
11

Y160L-2

18.5

9-19 6.3A
2900
1
2
3
4
5
6
7
9149
9265
9219
9055
8857
8543
8148
3220
3865
4509
5153
5690
6334
6978
12.5
14.5
16.4
18.4
20.2
22.5
25.1

Y160L-2

18.5

Y200L1-2

30

9-19 7.1D
2900
1
2
3
4
5
6
7
11717
11868
11807
11596
11340
10935
10426
4610
5532
6454
7376
8144
9066
9988
23.3
27.0
30.5
34.1
37.5
41.8
46.5

Y200L2-2

37

Y250M-2

55

9-19 8D
2900
1
2
3
4
5
6
7
15034
15229
15151
14877
14546
14021
13362
6594
7913
9232
10550
11649
12968
14287
42.3
49.0
55.4
62.0
68.2
75.9
84.4

Y280S-2

75

Y315S-2

110

9-19 8D
1450
1
2
3
4
5
6
7
3620
3665
3647
3584
3507
3384
3231
3297
3957
4616
5275
5825
6484
7144
5.5
6.1
6.9
7.7
8.5
9.5
10.6

Y132M-4

7.5

Y160L-4

15

9-19 9D
1450
1
2
3
4
5
6
7
4597
4655
4632
4551
4453
4297
4101
4695
5633
6572
7511
8294
9233
10171
9.5
11.0
12.5
14.0
15.4
17.1
19.0

Y160L-4

15

Y180L-2

twenty two

9-19 10D
1450
1
2
3
4
5
6
7
5840
5941
5891
5740
5495
5244
4958
6440
7942
9445
10947
12450
13952
15455
15.7
18.8
21.8
24.8
28.0
31.4
35.1

Y200L-4

30

Y225S-4

37

9-19 11.2D
1450
1
2
3
4
5
6
7
7364
7491
7428
7236
6927
6609
6246
9047
11158
13269
15380
17491
19602
21713
27.7
33.2
38.4
43.7
49.3
55.4
61.8

Y225M-4

45

Y280S-4

75

9-19 11.2D
960
1
2
3
4
5
6
7
3182
3237
3210
3128
2996
2860
2705
5990
7388
8785
10182
11580
12978
14375
8.0
9.6
11.2
12.7
14.3
16.1
17.9

Y180L-6

15

Y200L2-6

twenty two

9-19 12.5D
1450
1
2
3
4
5
6
7
9229
9390
9310
9068
8678
8278
7822
12577
15512
15447
21381
24316
27251
30186
47.9
57.4
66.6
75.6
85.4
95.9
107.0

Y280S-4

75

Y315S-4

110

9-19 12.5D
960
1
2
3
4
5
6
7
3975
4043
4009
3907
3741
3571
3377
8327
10270
12213
14156
16099
18042
19985
13.9
16.7
19.3
21.9
24.8
27.8
31.1

Y200L-6

twenty two

Y250M-6

37

9-19 14D
1450
1
2
3
4
5
6
7
11668
11874
11771
11464
10967
10457
9878
17670
21793
25916
30040
34163
38286
42409
84.5
101.2
117.3
133.3
150.5
169.1
188.6

Y315M-4

132

Y355M-4

220

9-19 14D
960
1
2
3
4
5
6
7
5004
5090
5047
4917
4709
4494
4249
11699
14428
17158
19888
22618
25348
28078
24.5
29.4
34.0
38.7
43.7
49.1
54.7

Y250M-6

37

Y315S1-6

75

9-19 16D
1450
1
2
3
4
5
6
7
15425
15700
15563
15151
14488
13808
13035
26377
32531
38686
44841
50995
57150
63305

164.6
197.2
228.7
259.9
293.3
329.6
367.6

Y355M3-4

315

JS138-6

410

9-19 16D
960
1
2
3
4
5
6
7
6570
6683
6627
6456
6180
5898
5575
17463
21538
25613
29687
33762
37837
41912
47.8
57.2
66.4
75.4
85.1
95.7
106.7

Y315S-6

75

Y315L1-6

110

4

9-19 series high pressure centrifugal fan installation and external dimensions





5

9-19 Series High Pressure Centrifugal Fan Installation Guide


1. Before installation, check whether the impeller and casing are deformed smoothly due to transportation, and check whether the joints are fastened; otherwise, they can be installed and used after being repaired.
2. The inlet and outlet of the fan should have sufficient strength, rigidity, stability and durability.
3. The fan must be installed tightly and must be installed using the anchor bolt holes of the fan or motor.
4. It is strictly forbidden to use the inlet and outlet flanges as the mounting force. The weight of the air duct should be supported by rigid support.
5. If there is an elbow or a sudden change in the section of the pipe within twice the diameter of the wind wheel before and after the air inlet and outlet, the pipe resistance will increase sharply and should be avoided if possible.
6. The power supply must ensure three-phase balance without defects. The voltage can fluctuate within ± 5% of the rated voltage.
7. Professionals must be responsible for motor wiring to ensure correct wiring.
8. Fatal damage caused by sundries entering the fan should be considered during installation, and corresponding protective parts should be provided.
9. It is best to increase the air volume adjustment valve in the pipe network system in order to adjust the operating point of the fan.
6

9-19 High-pressure oblique flow centrifugal fan use, maintenance and precautions

1. Before using the fan, first check whether there are any items in the fan and pipeline that hinder the rotation.
2. Before the wind turbine is officially used, it must be tested and the following items must be determined:
A. The wiring is correct. B. There is no abnormal noise from the fan. C. Power is not overloaded
D. The direction of fan rotation is the same as marked. E. Fully open the test machine for no more than 3 minutes.
3. The fan can't be used under the condition that the air inlet and outlet are not connected to the pipeline, otherwise the motor will be burned due to overload.
6. Gases delivered:
(1) No sticky substances are allowed.
(2) The dusty hard particles contained in the medium cannot be more than 150mg / m3.
7. The fan cannot be started and stopped too frequently, otherwise the motor will be burned.
8. Do not allow sundries to block the air inlet and outlet of the motor cooling fan and the cooling teeth on the surface of the motor to prevent the motor from being burned due to poor heat dissipation of the motor.
9.Regularly clean up the dust and oil on the surface of the wind wheel to prevent the vibration of the wind wheel from being damaged due to damage to the dynamic balance of the wind wheel.
7

Common failures and causes of 9-19 series high pressure centrifugal fans


1.The fan vibrates violently
(1) The fan shaft is not concentric with the motor shaft and the pulley grooves are misaligned
(2) The friction between the casing or the air inlet and the impeller;
(3) The stiffness of the foundation is insufficient or not strong;
(4) Loose or deformed impeller rivets;
(5) Looseness of the impeller shaft disc hole and shaft;
(6) Loose bolts such as housing, bearing housing and bracket, bearing housing and bearing cover;
(7) Poor installation of fan inlet and outlet pipelines, causing resonance;
(8) The blade has ash, dirt, blade wear, impeller deformation, shaft bending and other reasons that make the rotor unbalanced.

2, bearing temperature rise is too high
(1) Vibration of the bearing box;
(2) The quality of the lubricant is not good, it is deteriorated or contains impurities such as dust, sand, dirt, etc.
(3) The tightening force of bearing box cover and seat connecting bolt is too large or too small;
(4) The shaft and rolling bearing are installed at an angle, and the front and rear axes are not concentric;
(5). The rolling bearing is damaged or the shaft is bent.

3.The motor current is too large or the temperature rise is too high
(1) The gates of the inlet and outlet pipes are not closed when driving;
(2) Low motor input voltage or single-phase power failure;
(3) Affected by the severe vibration of the bearing box;
(4) The spindle speed exceeds the rated value.

  • Yunnan Jingge Ventilation Equipment Co., Ltd.
  • Dabanqiao Industrial Park, Guandu District, Kunming City, Yunnan Province
  • 714328283@qq.com
  • hotline:
  • 13759168650
  • Jing grid fan-believe in the power of the brand
Copyright © Yunnan Jingge Ventilation Equipment Co., Ltd. All Rights Reserved. Dian ICP No.16007375-1 Website Construction Technical Support: Yunnan Dinghao Information Technology Co., Ltd
七乐彩 欢乐拼三张 欢乐拼三张 天天电玩城